The main purpose of setting an extended arm truss between the outer frame column and the core tube is to reduce structural lateral displacement. Its mechanism is to increase the axial force of the outer frame column under horizontal loads, thereby increasing the overturning moment borne by the frame and reducing the overturning moment of the core tube. Its anti bending effect on the structure can effectively increase the lateral stiffness of the structure, reduce the lateral movement of the structure, and generally also reduce the shear sharing ratio of the outer frame. For the core tube structure of the frame, setting up an extended arm truss significantly reduces lateral displacement, while for the tube in tube structure, the effect of reducing lateral displacement is very small.
The function of setting up a waist truss around the structure is to uniformly change the axial force borne by each frame column, thus improving the ability of the outer frame to resist overturning moment and reducing lateral displacement, but it is not as effective as extending the arm. In the frame core tube structure, depending on the number and arrangement of external frame columns, waist trusses can be set or not set; Due to the fact that waist truss can reduce the shear lag of frame tube structures, waist truss can increase the overall stiffness of the structure and reduce its lateral displacement in tube in tube structures.
The structure can be designed with only one or both of the above components depending on the specific situation. Floors with extended arm trusses and waist trusses can be collectively referred to as reinforced floors.
After setting up the reinforcement layer, the stiffness of the structure along the height direction is uneven, and the sudden change in stiffness brings about a sudden change in internal force. Therefore, there will be significant changes in the internal force of the components in the reinforcement layer and adjacent layers. The setting is a directional change, and the greater the stiffness of the reinforcement layer, the greater the degree of internal force mutation, which will produce a weak layer effect.
Therefore, in the wind resistant design of structures, the use of extended arm trusses and waist trusses has a good effect. It can use reinforced layers with high stiffness to form a larger lateral stiffness.
In seismic design structures, the adverse effects caused by weak layers should be minimized as much as possible. Therefore, when it is not necessary to set up a strengthening layer, it is not necessary to set up a strengthening layer. When a strengthening layer is needed, it is also not advisable to use excessively rigid extension arms and waist trusses to avoid excessive stiffness changes in the scope of the strengthening layer.
Arm trusses and waist trusses can be arranged along the height for one floor (one track) or multiple floors (multiple tracks). Research has shown that the effect of reducing lateral displacement is better for multi track extended arm trusses than for single track extended arm trusses, but the number of extended arm structures is not directly proportional to the reduction of lateral displacement. When more than four extended arm trusses are installed, the effect of reducing lateral displacement is no longer significant.
The effect of reducing lateral displacement varies depending on the position of the extension arm. Research has shown that when only one extension arm truss is installed along the height, it can be set at 2/3H of the structure to achieve the best effect of reducing lateral displacement. However, to reduce the overturning moment of the inner tube, the lower the better; When setting up two boom trusses, one can be set at a height of 0.7H, and the other can be set at approximately 0.5H. In general high-rise structural design, sensitivity analysis is required to determine the most effective and suitable position for the extended arm truss in order to study its specific structure.
The setting of the waist truss in the tube in tube structure depends on the effect of reducing shear lag.
Due to the different types of specific structures and building layouts, the reinforcement layer of the structure should generally be consistent with the equipment layer and refuge layer of high-rise buildings. However, emphasis should be placed on the cooperative optimization of building mechanics and structure, including the position and quantity of reinforcement layers.
From a specific technical perspective, the stiffness of the extended arm truss and waist truss should not be too high. If a reinforced concrete solid web beam with a whole floor height is used, not only will the stiffness suddenly change too much, but the upper and lower frame columns connected to it will be very unfavorable. These columns are prone to plastic hinges, cracks, and even damage, presenting an unfavorable seismic concept of "strong beams and weak columns". Therefore, both the extended arm truss and the waist truss should adopt truss structures, with steel structures being easier to construct and superior to steel reinforced concrete trusses.
Due to the adverse effects of installing reinforcement layers in seismic structures, the stiffness of the reinforcement layer is much greater than that of other floors, and there is a sudden change in internal forces. Therefore, the seismic performance of the reinforcement layer and the vertical components adjacent to the reinforcement layer should be improved.
In general, the seismic construction measures for reinforced concrete components in the upper and lower adjacent floors should be raised by one level, and may not be raised if it is a special level.
The upper and lower chords of the extended arm truss are important components of the truss, which inevitably undergo tensile and compressive deformation. Sometimes, the floor slab happens to be at the same elevation. Therefore, if the calculation is based on the assumption of infinite stiffness of the floor slab, the extended arm truss should be separated to release the tensile and compressive deformation of the upper and lower chords. Alternatively, when calculating, the floor slab adopts the assumption of elastic membrane. In actual design, different construction measures and calculation assumptions need to be proposed based on the specific situation in the strengthening layer.
When the extended arm truss or waist truss is used as a transfer layer component, it is not only necessary to verify its vertical deformation and bearing capacity, but also special and strict requirements should be put forward for the seismic performance of such components.
In high-intensity fortification areas, further performance design requirements and measures should be taken when strengthening floors are installed in tall or particularly irregular high-rise buildings. In order to ensure its safety under medium or large earthquakes, its members and adjacent members can be required to not yield under medium or large earthquakes, or even higher performance requirements. Based on the height and importance of the structure, it is advisable to use static elastic-plastic analysis or time history analysis to test the performance of the structure under medium and large earthquakes, in order to evaluate its ability to achieve the design seismic performance goals.
The extended arm truss is connected to the waist truss, outer frame frame, and core tube. In addition to designing according to the seismic resistance level of one level, the following measures need to be taken into consideration in actual design.